For an alarm system to function properly after a VoIP installation, where should the twisted-pair wires from the EMTA be connected?

To the alarm panel directly

To the RJ31X jack as the first device

In a VoIP installation, connecting the twisted-pair wires from the EMTA (Embedded Multimedia Terminal Adapter) to the RJ31X jack as the first device ensures the proper operation of the alarm system. The RJ31X jack is specifically designed for alarm systems to interface with telephone lines. This setup allows the alarm system to seize the line when it needs to communicate, which is crucial for emergencies or notifications.

The RJ31X jack provides a pathway for the alarm signal to be sent to the monitoring service even if a phone call is in progress, ensuring that alarm signals can be transmitted reliably. If the alarm panel were connected directly to the panel or to any device other than the RJ31X jack, there could be interruptions or failures in the signal transmission, compromising the effectiveness of the alarm system. Thus, the correct usage of the RJ31X jack is essential for maintaining proper functionality in an environment where VoIP is used.